Reasons for the cracking of the ceramic cup embryo body There are 7 main reasons for the cracking of the ceramic cup embryo body edge as follows: 1. The drying speed is too fast. 2. The rim of the vessel is too thin to withstand external forces. 3. If a ceramic cup has just been made and cracks begin to appear before any important drying stage, it may be that the mud has been used too many times. It is also possible that the additional filler (clinker or sand) in the mud is excessive. Sometimes, the recycled or re-allocated mud may become unusable because it has been used too many times, for example Mud that has been repeatedly drawn on a drawing machine. 4. When glazing the ceramic cup body, when it encounters the bonding part with too large thickness gap, it is easy to cause the thinner part (usually the mouth edge of the booklet) to be too wet, and these parts will be dried later in the process Withstand the intrusion of external forces. 5. When the dried body is placed in a humid environment, the body will absorb water again. This phenomenon is quite special. I have personally seen an example in which a semi-dry body absorbs water again, and when the body softens to a certain degree, it is crushed by its own weight. When a dry body is placed in a humid environment, the body will expand while absorbing moisture again, which will form a tensile force in the part with a large thickness difference in the later drying process. Those ceramic cup blanks with relatively small clay content, such as some low-temperature white clay and porcelain white porcelin dinnerware clay, have too low green strength to withstand the tensile force generated during the re-absorption process, and many small cracks appear, and these small cracks are only It can only be seen after unbaked. 6. One of the most common reasons is improper trimming. The trimming tool must be very sharp and can only be cut or shaved after the blank is half-dry. When the green body is too dry, its strength is very weak. In this case, when the green body is repaired, the green body is easily cracked by the repair tool. As mentioned in the previous article, small cracks on the outer surface of the blank will double the pressure. Generally speaking, after the trimming is completed, the outer surface of the billet is wiped smooth with a wet sponge, which can effectively prevent cracking. 7. In the field of ceramic industrial production, the cracking method on the edge of the plate is called 'bird's beakPut the dry or nearly dry plate on the electric turntable, and trim the edge of the plate at an appropriate angle with the help of an 'L'-shaped trimming knife. If the angle of the contact part between the trimming knife and the blank body is not appropriate, the knife edge will jump quickly and collide or strain the outer surface of the vessel, and the resulting cracking will appear after firing.
catering serveware is an inevitable and critical part of being a manufacturer, and it's more complicated than just manufacturing products and serving customers.
Above all, we expect to be a credit to the communities we serve, a valuable resource to our customers, and a place where our dedicated catering crockery wholesalers can grow and prosper.
Porcelain Dish Set catering tableware quality is more important because some how it affects to our Ceramic Dinnerware Sets. So grab good quality .
Guangdong Hosen Two Eight Ceramics Co.,Ltd is an expert in manufacturing a wide range of . We also have high quality Porcelain Dish Set and many others. Visit to know more.
Guangdong Hosen Two Eight Industrial Co.,Ltd. is a professional ceramic tableware manufacturer. It is committed to provide customers with one-stop purchasing service for hotel supplies and catering suppliers about 20 years by now. Sitemap
CONTACT US
Mobile: +86-18998415146
TEL: +86-20-39928600
E-mail: hosen-9@28ceramics.com
Office Address: 3/F-4/F, Shaxi International Hotel Supplies City, Shaxi Village, Guangzhou City, China
Factory Address: Ditou lndustrial Zone, Fengxi District, Chaozhou City, China